COMPARATIVE ANALYSIS OF GLOMERULAR FILTRATION RATE ASSESSMENT METHODS IN KIDNEY TRANSPLANT RECIPIENTS

Zhaklina SHTERJOVA-MARKOVSKA, Irena RAMBABOVA-BUSHLJETIK, Tanja MAKAZLIEVA, Aleksandra PESHEVSKA, Venjamin MAJSTOROV, Nikola GJORGJIEVSKI, Galina SEVEROVA, Dragan CIBREV, Oliver STANKOV, Vlatko KARANFILOVSKI, Goce SPASOVSKI

Experimental and Clinical Transplantation - 2026;24(10):806-816

University Clinic of Nephrology, Skopje, North Macedonia

 

Objectives: Accurate assessment of glomerular filtration rate is crucial for clinical follow-up of kidney transplant recipients. We evaluated agreement and performance of 3 serum creatinine-based equations (MDRD, race-free CKD-EPI 2021, and EKFC) relative to a clinically available measured glomerular filtration rate comparator method based on 99mTc-DTPA plasma clearance. Materials and Methods: In this single-center cross-sectional study, we evaluated 62 stable kidney transplant recipients (1-3 years posttransplant). Measured glomerular filtration rate was determined using the comparator method with a nuclear medicine slope-intercept technique and a 3-plasma sample method. We assessed equation performance using repeated-measures analysis of variance with Bonferroni-adjusted pairwise comparisons, correlation analysis, Bland-Altman mean bias and 95% limits of agreement, mean absolute error, and P30 accuracy across measured glomerular filtration rate, sex, age, and body mass index subgroups. Results: Most recipients were male (n = 44, 71%), with mean age of 40.98 +/- 11.46 years. Measured glomerular filtration rate (in mL/min/1.73 m 2) was <60 in 50 recipients (low filtration) and >=60 in 12 recipients (high filtration). In the low filtration subgroup, CKD-EPI 2021 and EKFC overestimated measured glomerular filtration rate obtained with the comparator method (mean bias -8.14 and -6.80 mL/min/1.73 m 2), whereas MDRD showed the smallest absolute mean bias (-1.63 mL/min/1.73 m 2) and the highest P30 accuracy (90.0%). In the high filtration subgroup, EKFC showed a near-zero mean bias (-0.27 mL/min/1.73 m 2). However, 95% limits of agreement remained wide, with limited interpretation because of small subgroup size. In recipients with obesity, all equations showed higher mean absolute error and substantial interindividual variability. Conclusions: Among serum creatinine-based equations, MDRD showed the closest agreement with the 99mTc-DTPA comparator method, particularly in the low filtration subgroup; EKFC findings in the high filtration subgroup required cautious interpretation. Multi-center studies, ideally including cystatin C-based and combined creatinine-cystatin C equations, are needed for further validation.