ELECTROANALYTICAL DETERMINATION OF SALBUTAMOL IN PHARMACEUTICAL FORMULATIONS USING CATHODICALLY PRETREATED BORON-DOPED DIAMOND ELECTRODE

PINAR TALAY PINAR, HOSHYAR SAADİ ALİ, ABDULLAH ABDULWAHED ABDULLAH, YAVUZ YARDIM, ZÜHRE ŞENTÜRK

Journal of Research in Pharmacy - 2018;22(3):460-468

Van Yüzüncü Yıl University, Faculty of Pharmacy, Department of Analytical Chemistry, Van, Turkey

 

This paper examined for the first time the possibilities of the usage of the cathodically pretreated boron-doped diamond (CPT-BDD) electrode for the redox behavior of salbutamol (SAL) using cyclic and adsorptive stripping voltammetry. The cyclic voltammograms showed an irreversible and adsorption-controlled oxidation peak at about +1.0 V in the Britton-Robinson (BR) buffer (pH 9.0) solution. Under the optimized experimental condition, using square-wave adsorptive stripping mode, the compound yielded a well-defined voltammetric response in BR buffer, pH 9.0 at +0.95 V (vs. Ag/AgCl) (after 30 s accumulation at an open circuit condition). A linear calibration graph was obtained in the concentration range of 4.15 to 83 μg mL-1 (1.73x10-5 -3.47x10-4 M). A detection limit of 1.21 μg mL-1 (5.06x10-6 M) was observed. The suggested method was also applied to the determination of SAL in the drug formulations.